Xiamen Changxuyuan Trading Co., Ltd
Email: sales@cxytrade.com TEL: +86--15959497059
Home > Products > Schneider Electric PLC >
TM3AI4 Schneider Electric Modicon M3 Logic Analog Input Module Original
  • TM3AI4 Schneider Electric Modicon M3 Logic Analog Input Module Original
  • TM3AI4 Schneider Electric Modicon M3 Logic Analog Input Module Original
  • TM3AI4 Schneider Electric Modicon M3 Logic Analog Input Module Original
  • TM3AI4 Schneider Electric Modicon M3 Logic Analog Input Module Original
  • TM3AI4 Schneider Electric Modicon M3 Logic Analog Input Module Original
  • TM3AI4 Schneider Electric Modicon M3 Logic Analog Input Module Original
  • TM3AI4 Schneider Electric Modicon M3 Logic Analog Input Module Original

TM3AI4 Schneider Electric Modicon M3 Logic Analog Input Module Original

Place of Origin France
Brand Name Schneider Electric
Certification COO & COC
Model Number TM3AI4
Product Details
Packing Size:
24*90*70 Mm
Warranty:
1 Year
Customer Courier A/C:
Yes – DHL/FedEx/UPS Account Accepted
Trade Terms::
EXW, DAP, FOB, CIF
Condition:
Brand New And Original
Shipping Weight:
0.2kg
Express Delivery:
DHL (default) / FedEx / UPS / TNT / Air / Sea
Highlight: 

Schneider Electric Modicon M3 module

,

Modicon M3 analog input module

,

PLC analog input module original

Payment & Shipping Terms
Minimum Order Quantity
1
Price
$90
Packaging Details
Brand new and original
Delivery Time
3-5 days
Payment Terms
T/T,Alipay,Paypal
Supply Ability
99+
Product Description

Product pictures

TM3AI4 Schneider Electric Modicon M3 Logic Analog Input Module Original

Product Overview: Schneider Electric TM3AI4

Parameter Specification
Manufacturer Schneider Electric 
Part Number TM3AI4
Product Range Modicon M3 Logic
Device Type Analog Input Expansion Module

Application & Fault Scenarios

Typical Uses: Temperature transmitter interfacing, pressure sensor scaling, level monitoring, process variable logging in compact M3 systems.
Common Field Issues:
  • Incorrect DIP/jumper setting → channel reads zero or saturated
  • Ground loop noise on unshielded cable → erratic readings near motors/VFDs
  • Spring terminal not fully seated → intermittent open-circuit fault flag
Note: Auto-detected by M3 CPU at power-up; no manual configuration tag needed.

Related products

TM3AI8 TM3AO2
TM3AO4 TM3DI8
TM3DO8 TM3DQ8R
TM3TI4 TM3TI8
TM3XCA1 TM3XBB1
TM3XBC1 TM3XBM1
TM3XBP1 TM3XBR1
TM3XBT1 TM3XBV1
TM3XCV1 TM3XDV1
TM3XFV1 TM3XGV1

FAQ

Q1: Does TM3AI4 need separate 24 VDC power?
A: No. It is fully bus-powered through the TM3 side connector; no external supply wiring required.
Q2: Can I mix voltage and current inputs on different channels?
A: Yes. Each channel is independently configurable via software; no hardware jumper changes needed.
Q3: How to confirm this is an authentic Schneider module?
A: Unique laser-marked serial on the side label is verifiable through Schneider’s official product validation portal. Manufactured in France with complete compliance documentation.

CONTACT US AT ANY TIME

+8615959497059
Room 202-5, Building 21, Wanghai Road, Software Park 2, Huli District, Xiamen, Fujian China 361008
Send your inquiry directly to us