Place of Origin France
Brand Name Schneider Electric
Certification COO & COC
Model Number VX5A1HD9011
Product Details
Shipping Weight:
2.6kg
Warranty:
1 Year
Packing Size:
395 × 260 × 55 Mm
Express Delivery:
DHL, FedEx, UPS
Condition:
Brand New And Original
Trade Terms::
EXW, DAP, FOB, CIF
Payment & Shipping Terms
Minimum Order Quantity
1
Price
$500
Packaging Details
Brand new and original
Delivery Time
3-5 days
Payment Terms
T/T,Alipay,Paypal
Supply Ability
99+
Product Description

VX5A1HD9011 Schneider Electric Original 110kW Power Board for Altivar Process ATV600 ATV900 VFD Drive Control PCB


The Schneider Electric VX5A1HD9011 is an original power board (drive control PCB) designed for Schneider Altivar Process ATV600 and ATV900 series variable frequency drives in the 90–110kW frame class. Mounted inside the drive power stage, this board executes PWM signal generation, IGBT gate driving, DC bus monitoring, and current/voltage feedback processing, forming the core interface between the control unit and the inverter output stage.
Engineered with reinforced isolation, precision current-sensing channels, and robust surge-tolerant circuitry, the VX5A1HD9011 maintains accurate switching timing and reliable protection response under continuous heavy-duty industrial operation. 
Replacing a faulty power board with a genuine Schneider Electric VX5A1HD9011 resolves drive issues such as output imbalance, SCF/OCF fault trips, unstable motor torque, and intermittent shutdown caused by damaged gate drive or sensing circuits. 

Product Specifications: Schneider Electric VX5A1HD9011 



Parameter Specification
Brand Schneider Electric
Part Number VX5A1HD9011
Product Type Power Board / Drive Control PCB
Application Schneider Altivar Process ATV600 / ATV900 VFD
Drive Frame Class 90–110 kW
Function PWM Generation / IGBT Gate Drive / Current & Voltage Monitoring


Product pictures


 

VX5A1HD9011 Schneider Electric Original 110kW Power Board for Altivar Process ATV600 ATV900 VFD Drive Control PCB

 

Related products



VX5A1HD18N4 VX5A1HC1113
VX5A1HD22N4 VX5A1HD30N4
VX5A1HD37N4 VX5A1HD45N4
VX5A1HD55N4 VX5A1HD75N4
VX5G48C21Q VX4G48165Q
VX5IM2300M1271 VX5IM2400M1271
VX5VPS4001 VX5A1HD11N4
VX5A1HU55N4 VX5A1HU75N4
VX5A1HD9013 VX5A1HC1613
VX4G481 VX5A1HD1113

 

FAQ


Q1: What is the Schneider Electric VX5A1HD9011?
A: It is an original power board for Schneider Altivar Process ATV600/ATV900 VFD drives, handling PWM generation, IGBT gate driving, and power stage monitoring.
Q2: What drive faults does the VX5A1HD9011 fix?
A: It resolves output imbalance, SCF/OCF fault trips, unstable torque, and intermittent shutdowns caused by a damaged drive control board.
Q3: Is the Schneider VX5A1HD9011 a genuine original board?
A: Yes. We supply authentic Schneider Electric power boards, each tested for PWM waveform integrity, isolation strength, and protection trip response before dispatch.

CONTACT US AT ANY TIME

+8615959497059
Room 202-5, Building 21, Wanghai Road, Software Park 2, Huli District, Xiamen, Fujian China 361008
Send your inquiry directly to us