2026-09-08
The SICK i110-RA223 6025108 is an electromechanical safety switch designed for machine guarding and safety-related monitoring applications. As part of the SICK i110R series, this safety switch provides positive-opening contacts and is designed to monitor the position of movable machine guards.
For maintenance teams, machine builders, automation engineers, and industrial spare-parts buyers, the SICK i110-RA223 is a practical solution when a reliable safety switch is required for machine access protection.
The SICK i110-RA223 is an electromechanical safety switch with a turning lever actuator. Its product number is 6025108.
According to the SICK datasheet, the i110-RA223 has two positive-opening normally closed contacts and two normally open contacts. It supports four actuation directions and uses a cable entry with one M20 connection.
| Product Information | Details |
|---|---|
| Brand | SICK |
| Product Series | i110R |
| Model | i110-RA223 |
| Part Number | 6025108 |
| Product Type | Electromechanical Safety Switch |
| Actuator | Turning Lever |
| Positive-Opening N/C Contacts | 2 |
| N/O Contacts | 2 |
| Actuation Directions | 4 |
| Cable Entry | 1 × M20 |
| Switching Principle | Slow-action switching element |
| Usage Category | AC-15 / DC-13 |
| Rated Operating Current | 3 A at 240 V AC / 3 A at 24 V DC |
| Rated Insulation Voltage | 250 V |
| Standard | EN ISO 14119 |
The specifications above are based on SICK's published product data for i110-RA223 / 6025108.
A machine guard safety switch is used to monitor whether a movable protective guard, door, cover, or access point is in the required position.
In industrial automation systems, access to hazardous areas may need to be monitored before certain machine operations are allowed. A safety switch can provide a switching signal to the connected safety-related control logic.
The SICK i110-RA223 6025108 is designed for this type of application. Its positive-opening normally closed contacts are particularly relevant to safety-related guard monitoring.
Typical applications can include:
Machine safety doors
Protective covers
Industrial machine guards
Production machinery
Packaging machines
Material handling equipment
Automated production lines
Industrial manufacturing equipment
![]()
The i110-RA223 provides two positive-opening N/C contacts together with two N/O contacts. This contact configuration can be integrated into appropriate machine safety circuits according to the system design.
For replacement buyers, checking the contact configuration is important because a visually similar safety switch may not have the same electrical configuration.
The SICK datasheet specifies four actuation directions for the i110-RA223.
This provides flexibility when installing the safety switch on machinery with different guard and actuator arrangements.
The i110-RA223 uses a turning lever actuator design. This makes it suitable for machine guarding applications where the mechanical movement of a guard needs to operate the switch.
When replacing an existing safety switch, buyers should verify the actuator design, mounting arrangement, contact configuration, and mechanical operating direction before ordering.
The model uses one M20 cable entry, with a conductor cross section of up to 2.5 mm² according to the SICK datasheet.
This is an important specification to check when replacing a safety switch because cable entry and wiring requirements can affect installation compatibility.
The SICK i110-RA223 uses a slow-action switching element and is specified for AC-15/DC-13 utilization categories.
Its rated operating current is 3 A at 240 V AC and 3 A at 24 V DC, while the rated insulation voltage is 250 V.
For machine safety projects, the electrical characteristics should always be evaluated together with the complete safety circuit, connected safety logic, load, and applicable machine safety requirements.
The SICK datasheet specifies a B10d value of 2 × 10⁶ switching cycles under low load and identifies the switch as Type 1 according to EN ISO 14119. The actuator coding level is listed as uncoded.
An important point for engineers is that the switch itself does not provide internal fault detection. SICK states that fault detection is performed by the connected safety-related logic unit.
Therefore, the i110-RA223 should not be evaluated as an isolated component. Its suitability depends on the complete machine safety architecture and the applicable safety requirements.
![]()
Machine builders can use electromechanical safety switches to monitor access doors and movable guards on industrial machinery.
Production lines may contain multiple guarded areas. A safety switch can provide guard-position information to the relevant safety control system.
Packaging machinery often contains moving mechanisms and guarded access areas. Safety switches can be used as part of the machine's protective system.
Conveyors and automated material-handling equipment may use safety switches on access doors, covers, or guarded sections.
For maintenance teams, identifying the exact part number is essential when replacing an installed safety component.
The combination SICK i110-RA223 + 6025108 is particularly useful as a search reference because both the model number and part number can be used to identify the required component.
When replacing a SICK i110-RA223 6025108, do not select a replacement based only on appearance.
Check the following information first:
Confirm the manufacturer and exact model.
Verify the part number: 6025108.
Check the number and type of contacts.
Confirm the actuator/lever configuration.
Check the actuation direction.
Verify the cable entry and wiring requirements.
Check the electrical ratings.
Review the machine's existing safety circuit.
Confirm compatibility with the connected safety-related logic.
Follow the applicable machine safety procedures during installation.
For safety-related equipment, replacement and installation should be performed by appropriately qualified personnel and according to the equipment documentation and applicable regulations.
Industrial buyers searching for this component may use different combinations of the model number and product description.
Common search phrases include:
SICK i110-RA223
SICK 6025108
i110-RA223 6025108
SICK i110-RA223 safety switch
SICK electromechanical safety switch
SICK machine guard switch
machine guard safety switch
i110R safety switch
SICK safety switch replacement
Using both the model number and part number is especially important for industrial spare-parts searches because distributors and maintenance departments frequently search directly by the manufacturer's reference number.
If you are sourcing a SICK i110-RA223 6025108 for machine maintenance, replacement, or industrial spare-parts inventory, verify the exact part number before purchasing.
The product page for SICK i110-RA223 6025108 Safety Switch provides a direct reference for buyers looking for this specific model.
Recommended internal link anchor texts:
SICK i110-RA223 6025108
SICK 6025108 Safety Switch
i110-RA223 Machine Guard Safety Switch
SICK Electromechanical Safety Switch
SICK i110-RA223 is an electromechanical safety switch from the SICK i110R series, designed for safety-related monitoring of machine guards and movable access points.
The SICK i110-RA223 has the part number 6025108.
The model has 2 positive-opening normally closed contacts and 2 normally open contacts.
The i110-RA223 uses one M20 cable entry.
The datasheet specifies 3 A at 240 V AC and 3 A at 24 V DC for the applicable switching category.
The i110-RA223 is an electromechanical safety switch designed for safety-related applications involving machine guards and access monitoring. The complete application must be evaluated according to the machine's safety design and applicable standards.
The SICK i110-RA223 6025108 is a compact electromechanical safety switch for machine guard and access monitoring applications. Its combination of positive-opening contacts, four actuation directions, turning lever design, and M20 cable entry makes the exact model and part number important when selecting a replacement.
For maintenance engineers, automation integrators, machine builders, and industrial spare-parts buyers, searching by both SICK i110-RA223 and 6025108 can help identify the correct component more efficiently.
When purchasing or replacing the component, always verify the exact electrical and mechanical configuration against the installed equipment and the manufacturer's documentation.
CONTATO E.U.A QUALQUER HORA