SICK i110-RA223 6025108 Safety Switch for Machine Guards

2026-09-08

Najnowszy blog firmowy o SICK i110-RA223 6025108 Safety Switch for Machine Guards

The SICK i110-RA223 6025108 is an electromechanical safety switch designed for machine guarding and safety-related monitoring applications. As part of the SICK i110R series, this safety switch provides positive-opening contacts and is designed to monitor the position of movable machine guards.

For maintenance teams, machine builders, automation engineers, and industrial spare-parts buyers, the SICK i110-RA223 is a practical solution when a reliable safety switch is required for machine access protection.

SICK i110-RA223 6025108 Overview

The SICK i110-RA223 is an electromechanical safety switch with a turning lever actuator. Its product number is 6025108.

According to the SICK datasheet, the i110-RA223 has two positive-opening normally closed contacts and two normally open contacts. It supports four actuation directions and uses a cable entry with one M20 connection.

Product Information Details
Brand SICK
Product Series i110R
Model i110-RA223
Part Number 6025108
Product Type Electromechanical Safety Switch
Actuator Turning Lever
Positive-Opening N/C Contacts 2
N/O Contacts 2
Actuation Directions 4
Cable Entry 1 × M20
Switching Principle Slow-action switching element
Usage Category AC-15 / DC-13
Rated Operating Current 3 A at 240 V AC / 3 A at 24 V DC
Rated Insulation Voltage 250 V
Standard EN ISO 14119

The specifications above are based on SICK's published product data for i110-RA223 / 6025108.

What Is a Machine Guard Safety Switch?

A machine guard safety switch is used to monitor whether a movable protective guard, door, cover, or access point is in the required position.

In industrial automation systems, access to hazardous areas may need to be monitored before certain machine operations are allowed. A safety switch can provide a switching signal to the connected safety-related control logic.

The SICK i110-RA223 6025108 is designed for this type of application. Its positive-opening normally closed contacts are particularly relevant to safety-related guard monitoring.

Typical applications can include:

  • Machine safety doors

  • Protective covers

  • Industrial machine guards

  • Production machinery

  • Packaging machines

  • Material handling equipment

  • Automated production lines

  • Industrial manufacturing equipment

SICK i110-RA223 6025108 Safety Switch for Machine Guards

Key Features of the SICK i110-RA223

1. Two Positive-Opening Normally Closed Contacts

The i110-RA223 provides two positive-opening N/C contacts together with two N/O contacts. This contact configuration can be integrated into appropriate machine safety circuits according to the system design.

For replacement buyers, checking the contact configuration is important because a visually similar safety switch may not have the same electrical configuration.

2. Four Actuation Directions

The SICK datasheet specifies four actuation directions for the i110-RA223.

This provides flexibility when installing the safety switch on machinery with different guard and actuator arrangements.

3. Turning Lever Actuator

The i110-RA223 uses a turning lever actuator design. This makes it suitable for machine guarding applications where the mechanical movement of a guard needs to operate the switch.

When replacing an existing safety switch, buyers should verify the actuator design, mounting arrangement, contact configuration, and mechanical operating direction before ordering.

4. M20 Cable Entry

The model uses one M20 cable entry, with a conductor cross section of up to 2.5 mm² according to the SICK datasheet.

This is an important specification to check when replacing a safety switch because cable entry and wiring requirements can affect installation compatibility.

Electrical Specifications

The SICK i110-RA223 uses a slow-action switching element and is specified for AC-15/DC-13 utilization categories.

Its rated operating current is 3 A at 240 V AC and 3 A at 24 V DC, while the rated insulation voltage is 250 V.

For machine safety projects, the electrical characteristics should always be evaluated together with the complete safety circuit, connected safety logic, load, and applicable machine safety requirements.

Safety-Related Parameters

The SICK datasheet specifies a B10d value of 2 × 10⁶ switching cycles under low load and identifies the switch as Type 1 according to EN ISO 14119. The actuator coding level is listed as uncoded.

An important point for engineers is that the switch itself does not provide internal fault detection. SICK states that fault detection is performed by the connected safety-related logic unit.

Therefore, the i110-RA223 should not be evaluated as an isolated component. Its suitability depends on the complete machine safety architecture and the applicable safety requirements.

SICK i110-RA223 6025108 Safety Switch for Machine Guards

SICK i110-RA223 Applications

Industrial Machinery

Machine builders can use electromechanical safety switches to monitor access doors and movable guards on industrial machinery.

Automated Production Lines

Production lines may contain multiple guarded areas. A safety switch can provide guard-position information to the relevant safety control system.

Packaging Equipment

Packaging machinery often contains moving mechanisms and guarded access areas. Safety switches can be used as part of the machine's protective system.

Material Handling Systems

Conveyors and automated material-handling equipment may use safety switches on access doors, covers, or guarded sections.

Machine Replacement and Maintenance

For maintenance teams, identifying the exact part number is essential when replacing an installed safety component.

The combination SICK i110-RA223 + 6025108 is particularly useful as a search reference because both the model number and part number can be used to identify the required component.

How to Replace a SICK 6025108 Safety Switch

When replacing a SICK i110-RA223 6025108, do not select a replacement based only on appearance.

Check the following information first:

  1. Confirm the manufacturer and exact model.

  2. Verify the part number: 6025108.

  3. Check the number and type of contacts.

  4. Confirm the actuator/lever configuration.

  5. Check the actuation direction.

  6. Verify the cable entry and wiring requirements.

  7. Check the electrical ratings.

  8. Review the machine's existing safety circuit.

  9. Confirm compatibility with the connected safety-related logic.

  10. Follow the applicable machine safety procedures during installation.

For safety-related equipment, replacement and installation should be performed by appropriately qualified personnel and according to the equipment documentation and applicable regulations.

Why Buyers Search for SICK i110-RA223 6025108

Industrial buyers searching for this component may use different combinations of the model number and product description.

Common search phrases include:

  • SICK i110-RA223

  • SICK 6025108

  • i110-RA223 6025108

  • SICK i110-RA223 safety switch

  • SICK 6025108 safety switch

  • SICK electromechanical safety switch

  • SICK machine guard switch

  • machine guard safety switch

  • i110R safety switch

  • SICK safety switch replacement

Using both the model number and part number is especially important for industrial spare-parts searches because distributors and maintenance departments frequently search directly by the manufacturer's reference number.

SICK i110-RA223 6025108 for Industrial Spare Parts

If you are sourcing a SICK i110-RA223 6025108 for machine maintenance, replacement, or industrial spare-parts inventory, verify the exact part number before purchasing.

The product page for SICK i110-RA223 6025108 Safety Switch provides a direct reference for buyers looking for this specific model.

Recommended internal link anchor texts:

  • SICK i110-RA223 6025108

  • SICK i110-RA223 Safety Switch

  • SICK 6025108 Safety Switch

  • i110-RA223 Machine Guard Safety Switch

  • SICK Electromechanical Safety Switch

Frequently Asked Questions

What is SICK i110-RA223?

SICK i110-RA223 is an electromechanical safety switch from the SICK i110R series, designed for safety-related monitoring of machine guards and movable access points.

What is the part number of SICK i110-RA223?

The SICK i110-RA223 has the part number 6025108.

How many contacts does the i110-RA223 have?

The model has 2 positive-opening normally closed contacts and 2 normally open contacts.

What cable entry does the SICK 6025108 use?

The i110-RA223 uses one M20 cable entry.

What is the rated operating current?

The datasheet specifies 3 A at 240 V AC and 3 A at 24 V DC for the applicable switching category.

Is SICK i110-RA223 suitable for machine guards?

The i110-RA223 is an electromechanical safety switch designed for safety-related applications involving machine guards and access monitoring. The complete application must be evaluated according to the machine's safety design and applicable standards.

Conclusion

The SICK i110-RA223 6025108 is a compact electromechanical safety switch for machine guard and access monitoring applications. Its combination of positive-opening contacts, four actuation directions, turning lever design, and M20 cable entry makes the exact model and part number important when selecting a replacement.

For maintenance engineers, automation integrators, machine builders, and industrial spare-parts buyers, searching by both SICK i110-RA223 and 6025108 can help identify the correct component more efficiently.

When purchasing or replacing the component, always verify the exact electrical and mechanical configuration against the installed equipment and the manufacturer's documentation.

Skontaktuj się z nami w każdej chwili

+86--15959497059
Pokój 202-5, budynek 21, Wanghai Road, Software Park 2, Huli District, Xiamen, Fujian China 361008
Wyślij zapytanie bezpośrednio do nas