Xiamen Changxuyuan Trading Co., Ltd
Email: sales@cxytrade.com TEL: +86--15959497059
Home
Home
>
blog
>
Company blog about Schneider Electric LC1D65ABD 65A TeSys D Contactor with 24V DC Coil
Events
Leave A Message

Schneider Electric LC1D65ABD 65A TeSys D Contactor with 24V DC Coil

2026-09-14

latest company blog about Schneider Electric LC1D65ABD 65A TeSys D Contactor with 24V DC Coil

The Schneider Electric LC1D65ABD is a TeSys D three-pole contactor with a 65 A AC-3 rating and a 24 V DC standard coil. Designed for motor control and industrial electrical applications, this contactor is widely relevant to machine builders, maintenance engineers, electrical contractors, and industrial automation spare-parts buyers.

For customers searching for an exact replacement contactor, the complete part number LC1D65ABD is especially important. Searches such as Schneider LC1D65ABD, LC1D65ABD 65A contactor, and LC1D65ABD 24V DC can help identify the correct component.

Schneider Electric LC1D65ABD Overview

The LC1D65ABD belongs to the Schneider Electric TeSys D contactor family.

According to Schneider Electric's product data, the LC1D65ABD is a 3-pole contactor with 3 normally open power contacts, a 24 V DC standard coil, and a rated operational current of 65 A at up to 440 V AC under AC-3 conditions. It is designed for applications including motor control and resistive loads.

Product Information Details
Brand Schneider Electric
Product Family TeSys D
Model LC1D65ABD
Product Type Contactor
Poles 3P
Power Contacts 3 NO
Rated Current 65 A AC-3
Rated Voltage Up to 440 V AC
Coil Voltage 24 V DC
Coil Type DC standard
Auxiliary Contacts 1 NO + 1 NC
Applications Motor control, resistive loads
Utilisation Categories AC-1, AC-3, AC-4

The exact electrical rating should always be evaluated according to the application, operating conditions, and applicable standards.

What Is Schneider Electric LC1D65ABD?

The LC1D65ABD is an industrial contactor used primarily for switching and controlling electrical loads, particularly motors.

A contactor allows a control circuit to operate a higher-power electrical circuit. In industrial automation systems, the contactor may be controlled by a PLC output, relay, pushbutton station, or other control equipment.

The 24 V DC coil of the LC1D65ABD makes it suitable for control architectures where 24 V DC is used for industrial control circuits.

The three-pole configuration is intended for three-phase applications, while the 65 A AC-3 rating makes this model suitable for appropriately sized motor-control applications.

Key Features of LC1D65ABD

1. 65 A AC-3 Rating

The LC1D65ABD has a rated operational current of 65 A at up to 440 V AC under AC-3 conditions. Schneider Electric also specifies an AC-1 rating of up to 80 A at ≤440 V AC and ≤60°C.

The AC-3 rating is particularly relevant when the contactor is being selected for motor-control applications.

When replacing an existing contactor, engineers should compare the actual motor current and operating category rather than selecting a replacement based only on the "65 A" designation.

2. 24 V DC Standard Coil

The LC1D65ABD uses a 24 V DC standard coil.

This is one of the most important identification characteristics of this model.

When ordering a replacement, make sure the coil voltage matches the control circuit. A contactor with the same current rating but a different coil voltage may not be a suitable replacement.

3. Three-Pole, Three Normally Open Contacts

The LC1D65ABD has a 3P configuration with 3 normally open power contacts.

This configuration is suitable for switching three-phase motor circuits and other compatible industrial loads.

4. Auxiliary Contacts

Schneider Electric's product data lists 1 NO + 1 NC auxiliary contact composition for the LC1D65ABD.

Auxiliary contacts can be used for control, feedback, interlocking, and status-related functions depending on the machine's electrical design.

5. TeSys D Product Family

The LC1D65ABD is part of the TeSys D product family, making the exact family designation another useful identification term when searching for this contactor.

For industrial spare-parts procurement, using both the family name and complete reference number is recommended:

Schneider Electric + TeSys D + LC1D65ABD

LC1D65ABD Motor Control Applications

Industrial Motor Control

The contactor can be used to switch appropriately rated three-phase motors in industrial equipment.

Manufacturing Machinery

Industrial machinery often uses contactors as part of motor starters and electrical control systems.

Conveyor Systems

Conveyor motors may use contactors for starting, stopping, and control functions depending on the system architecture.

Pumps and Fans

Appropriately rated pumps and fans can use contactors as part of their electrical switching and motor-control circuits.

Industrial Automation Panels

The LC1D65ABD can be integrated into electrical control cabinets where a 24 V DC control circuit is used to operate a higher-power load.

HVAC and Industrial Equipment

Schneider Electric identifies TeSys contactors for industrial and HVAC applications, subject to appropriate application and rating requirements.

LC1D65ABD Electrical Selection Considerations

When selecting an LC1D65ABD, several specifications should be considered together.

Motor Current

The motor's actual operating current should be compared with the contactor's applicable AC-3 rating.

Coil Voltage

The existing control circuit should provide the required 24 V DC coil voltage.

Number of Poles

The LC1D65ABD is a three-pole contactor with three normally open power contacts.

Operating Category

Motor applications should be evaluated under the appropriate utilization category, such as AC-3.

Voltage

The power circuit voltage must remain within the contactor's applicable rating.

These checks are particularly important when replacing an installed contactor.

Schneider Electric LC1D65ABD 65A TeSys D Contactor with 24V DC Coil

Schneider LC1D65ABD Replacement Guide

If you are searching for a LC1D65ABD replacement, do not select a replacement solely by current rating.

Check the following:

  1. Confirm the original part number.

  2. Verify the 24 V DC coil.

  3. Confirm the three-pole configuration.

  4. Check the number and type of auxiliary contacts.

  5. Verify the motor's rated current.

  6. Confirm the utilization category.

  7. Check the power circuit voltage.

  8. Compare terminal and mounting requirements.

  9. Review the existing control-panel wiring.

  10. Confirm the replacement manufacturer's specifications before installation.

For safety and reliability, replacement work should be carried out by qualified personnel according to the equipment documentation and applicable electrical requirements.

Is Schneider LC1D65ABD Being Replaced?

This is particularly important for buyers searching for this model today.

Schneider Electric currently lists LC1D65ABD as a product approaching discontinuation and identifies LC1D65ABNE as a recommended replacement. The official US product page states a discontinuation date of December 31, 2026, while other Schneider regional pages show different regional lifecycle dates.

Schneider's recommended replacement, LC1D65ABNE, is a 65 A TeSys contactor with a 24–60 V AC/DC coil and EverLink connection technology.

However, a recommended replacement should not automatically be treated as a drop-in replacement for every installation. Buyers should compare coil requirements, terminals, dimensions, wiring, auxiliary contacts, and the complete machine/control-panel configuration before substitution.

This makes LC1D65ABD replacement an important search phrase for maintenance departments and industrial spare-parts buyers.

Why Buyers Search for LC1D65ABD

Industrial electrical buyers may use different search phrases depending on whether they are identifying a spare part, checking specifications, or looking for a replacement.

Common search terms include:

  • Schneider LC1D65ABD

  • LC1D65ABD

  • Schneider Electric LC1D65ABD

  • LC1D65ABD 65A contactor

  • LC1D65ABD 24V DC

  • Schneider TeSys D contactor

  • TeSys D 65A contactor

  • Schneider 65A contactor

  • LC1D65ABD replacement

  • LC1D65ABD spare part

  • LC1D65ABD equivalent

  • LC1D65ABD alternative

These keywords represent a mixture of exact-model searches, product-category searches, specification searches, and replacement intent.

LC1D65ABD for Industrial Spare Parts

For industrial maintenance teams, an exact part number can be more useful than a general product description.

If an existing electrical cabinet contains a Schneider Electric LC1D65ABD, the maintenance team should record the complete reference before ordering a replacement.

The product page for the Schneider Electric LC1D65ABD TeSys D 65A contactor can be used as a direct reference for buyers looking for this exact model.

When purchasing, verify:

  • Part number

  • Coil voltage

  • Current rating

  • Power circuit voltage

  • Contact configuration

  • Auxiliary contacts

  • Mounting arrangement

  • Terminal configuration

  • Application requirements

Schneider Electric LC1D65ABD 65A TeSys D Contactor with 24V DC Coil

Frequently Asked Questions

What is Schneider Electric LC1D65ABD?

The LC1D65ABD is a Schneider Electric TeSys D three-pole contactor with a 65 A AC-3 rating and a 24 V DC standard coil.

What is the coil voltage of LC1D65ABD?

The LC1D65ABD uses a 24 V DC standard coil.

How many poles does LC1D65ABD have?

The contactor has 3 poles and 3 normally open power contacts.

What is the current rating of LC1D65ABD?

Schneider Electric specifies 65 A at up to 440 V AC under AC-3 conditions. It is also rated up to 80 A under AC-1 conditions at ≤440 V AC and ≤60°C.

Is LC1D65ABD suitable for motor control?

Yes. Schneider Electric identifies motor control as one of the applications for this TeSys D contactor. The actual suitability depends on the motor characteristics, current, voltage, utilization category, and installation requirements.

What is the replacement for LC1D65ABD?

Schneider Electric currently lists LC1D65ABNE as a recommended replacement for LC1D65ABD. The replacement has a different 24–60 V AC/DC coil specification, so compatibility should be checked before substitution.

Conclusion

The Schneider Electric LC1D65ABD is a TeSys D three-pole contactor rated at 65 A under AC-3 conditions and equipped with a 24 V DC standard coil.

Its combination of 65 A rating, 24 V DC coil, 3P/3NO configuration, and TeSys D design makes the exact model relevant to industrial motor control, electrical control panels, machinery, and maintenance applications.

For buyers sourcing an original spare part, the complete reference LC1D65ABD should be verified before ordering. For replacement projects, Schneider Electric's current lifecycle information and recommended LC1D65ABNE successor should also be considered, while checking the complete electrical and mechanical compatibility of the installation.

CONTACT US AT ANY TIME

+86--15959497059
Room 202-5, Building 21, Wanghai Road, Software Park 2, Huli District, Xiamen, Fujian China 361008
Send your inquiry directly to us