EC10-4PT Emerson 4-Channel RTD Temperature Input Module for EC10 Micro PLC

Place of Origin UK / EU
Brand Name Emerson
Certification COO & COC
Model Number EC10-4PT
Product Details
Trade Terms::
EXW, DAP, FOB, CIF
Shipping Weight:
0.5KG
Packing Size:
160 × 130 × 110 Mm
Shipping:
DHL (default) / FedEx / UPS / TNT / Air / Sea
Customer Courier A/C:
Yes – DHL/FedEx/UPS Account Accepted
Express Delivery:
DHL, FedEx, UPS
Highlight: 

EC10-4PT RTD Temperature Module

,

4-Channel RTD Input Module

,

Emerson EC10 Micro PLC Module

Payment & Shipping Terms
Minimum Order Quantity
1 pc
Price
$50
Packaging Details
Brand new and original
Delivery Time
3-5 days
Payment Terms
T/T,paypal,alipay
Supply Ability
99+
Product Description

Product pictures

EC10-4PT Emerson 4-Channel RTD Temperature Input Module for EC10 Micro PLC

Product Overview: Emerson EC10-4PT

Parameter Specification
Manufacturer Emerson 
Order Number EC10-4PT 
Product Name Resistance Temperature Detector (RTD) Input Module — 4 channels
Series / Family EC10 micro programmable controller (PLC) — special function module group

Application & Fault Scenarios

Where It Fits: Adding temperature sensing to an existing EC10 machine control — for example extruder barrel zones, drying ovens, heat-seal bars, hydraulic oil and bearing monitoring — where the module feeds 4 RTD channels back into the PLC for display, alarm and interlock logic. It is also the standard replacement when an installed module fails or a cabinet is refurbished.
Faults Seen in the Field:
  • Wrong or wildly fluctuating temperature reading → check probe type matches the configuration (PT100 vs Cu100/Cu50), verify 3-wire sense wiring and probe resistance, and keep signal cable away from power and drive cables.
  • Channel reads open-circuit or maximum value → inspect the probe and terminal screws for looseness, corrosion or a broken element; test probe resistance at the terminals.
  • Module not recognised by the main module → reseat the expansion cable, confirm the cable is undamaged and correctly keyed, and check that the total expansion module count does not exceed 4.
  • Module dead, no status indication → measure the 24 VDC analog supply at the 24V+/24V− terminals and check the FG/earth connection.

Related products

EC10-1006BRA EC10-1006BTA
EC10-1410BRA EC10-1410BTA
EC10-1614BRA EC10-1614BTA
EC10-2416BRA EC10-2416BTA
EC10-3624BRA EC10-3624BTA
EC10-1614BRA1 EC10-1614BTA1
EC10-0800ENN EC10-0808ERN
EC10-0808ETN EC10-5AM
EC10-4TC EC10-4AD
Unidrive M702 Unidrive M703

FAQ

Q1: What is the Emerson EC10-4PT?
A: A 4-channel RTD temperature input module for the Emerson EC10 micro PLC — it accepts PT100, Cu100 or Cu50 sensors with 12-bit conversion and connects to the main module through the expansion cable.
Q2: Can it be used on its own?
A: No. It must be connected to a compatible EC10 main module; it has no CPU or program memory of its own.
Q3: How many expansion modules can an EC10 system carry?
A: Up to 4 in total, counting both digital I/O expansion modules and special function modules such as the EC10-4PT.