Xiamen Changxuyuan Trading Co., Ltd
Email: sales@cxytrade.com TEL: +86--15959497059
Home > Products > ABB Spare Parts >
SPAU140C ABB Synchro-Check Relay Dual-Stage for Generator Grid Connection
  • SPAU140C ABB Synchro-Check Relay Dual-Stage for Generator Grid Connection
  • SPAU140C ABB Synchro-Check Relay Dual-Stage for Generator Grid Connection
  • SPAU140C ABB Synchro-Check Relay Dual-Stage for Generator Grid Connection
  • SPAU140C ABB Synchro-Check Relay Dual-Stage for Generator Grid Connection
  • SPAU140C ABB Synchro-Check Relay Dual-Stage for Generator Grid Connection

SPAU140C ABB Synchro-Check Relay Dual-Stage for Generator Grid Connection

Place of Origin Sweden
Brand Name ABB
Certification COO & COC
Model Number SPAU140C
Product Details
Customer Courier A/C:
Yes – DHL/FedEx/UPS Account Accepted
Trade Terms:
EXW, DAP, FOB, CIF
Condition:
Brand New And Original
Packing Size:
144 Mm × 144 Mm × 190 Mm
Shipping Weight:
1.8 Kg
Shipping:
DHL (default) / FedEx / UPS / TNT / Air / Sea
Highlight: 

ABB Synchro-Check Relay for generators

,

Dual-stage generator grid connection relay

,

SPAU140C Synchro-Check Relay with warranty

Payment & Shipping Terms
Minimum Order Quantity
1
Price
$2100
Packaging Details
Brand new and original
Delivery Time
3-5 days
Payment Terms
T/T,Alipay,Paypal
Supply Ability
99+
Product Description

Product pictures

SPAU140C ABB Synchro-Check Relay Dual-Stage for Generator Grid Connection

Product Overview: ABB SPAU140C

Parameter Specification
Manufacturer ABB 
Model SPAU140C
Product Series SPACOM Protection Relays
Device Type Numerical synchro-check relay
Primary Function Synchro-check & voltage-check protection

Application & Fault Scenarios

Typical Uses: Monitors voltage, frequency, and phase angle between two power systems before closing a circuit breaker. Used in generator-to-grid synchronization, busbar paralleling, and transmission line reclosing. Dual-stage design supports simultaneous checking of two separate breakers.
Common Field Issues:
  • No sync permission → verify voltage inputs U1/U2/U3 are connected correctly; check that both sides of the breaker are energized; confirm sync window settings (ΔU, Δf, Δφ) are not too narrow.
  • IRF alarm (internal relay fault) → check auxiliary power supply (AC 80–265V / DC 18–80V); verify DIP switch voltage setting (100V vs 110V); inspect RS485 communication wiring.

Related products

SPAU130C SPAU140C-AA
SPAM150C SPAJ140C
SPAJ142C SPACU3D45
REF615 RET615
REG615 RED615
REB615 REU615
REV615 REF620
RET620 REX640
SPA-ZC_ Communication Module SPTU240R1 Power Module

FAQ

Q1: What is ABB SPAU140C?
A: The SPAU140C is a numerical synchro-check relay manufactured by ABB in Finland. It monitors voltage magnitude, frequency, and phase angle between two power systems and permits circuit breaker closing only when all parameters fall within preset synchronization windows.
Q2: What is the difference between synchro-check and voltage-check functions?
A: Synchro-check verifies that both sides of a circuit breaker have matching voltage, frequency, and phase angle before allowing closure (used when connecting two live systems). Voltage-check only verifies that a disconnected bus/line has acceptable voltage before connecting it to an energized network section.
Q3: How many circuit breakers can SPAU140C monitor?
A: The SPAU140C has two identical operation stages, allowing it to simultaneously check the closing conditions of two separate circuit breakers. Each stage has independent synchro-check and voltage-check functions.

CONTACT US AT ANY TIME

+8615959497059
Room 202-5, Building 21, Wanghai Road, Software Park 2, Huli District, Xiamen, Fujian China 361008
Send your inquiry directly to us